Decoding Dentium Lab Analogs: The Technical Differences Between DAN 34, DAN 38, DANSE, and DAN 38D
In implant dentistry, precision is the foundation of a successful restoration. One of the most critical steps in the laboratory workflow is selecting the correct laboratory analog, ensuring the master model accurately replicates the implant connection for a precise-fitting prosthesis.
As Dentium’s implant systems have evolved from the original SuperLine and Implantium platforms to the SuperLine II system, so too have the laboratory components. Understanding the differences between the legacy diameter-specific analogs and the newer universal manual and digital analogs is essential for achieving predictable restorative outcomes.
This guide explains the applications of DAN 34, DAN 38, DANSE, and DAN 38D, helping clinicians and dental laboratories select the appropriate component for every case.
The Legacy Foundation: DAN 34 and DAN 38
For the original SuperLine and Implantium implant systems, Dentium uses diameter-specific laboratory analogs. Each analog is designed to precisely replicate the connection geometry of a particular implant platform, ensuring optimal accuracy during model fabrication.
DAN 34 – Small Diameter Analog
The DAN 34 laboratory analog is specifically designed for small-diameter implants.
Compatible with:
- SuperLine (Legacy)
- Implantium
Compatible implant dimensions:
- Platform diameter: Ø3.6 mm
- Implant body diameter: Ø3.4 mm
Because of its unique connection geometry, the DAN 34 should only be used with these narrow-platform implants.
DAN 38 – Standard Analog for Regular and Wide Platforms
The DAN 38 is the standard laboratory analog for regular and wide-diameter restorations within the legacy Dentium systems.
Compatible with:
- SuperLine (Legacy)
- Implantium
Compatible platform diameters:
- Ø4.0 mm
- Ø4.5 mm
- Ø5.0 mm
- Ø6.0 mm
- Ø7.0 mm
For the majority of restorations using the original Dentium implant systems, the DAN 38 is the recommended laboratory analog.
The SuperLine II Evolution: DANSE and DAN 38D
With the introduction of SuperLine II, Dentium adopted a universal analog concept, significantly simplifying inventory management while maintaining restorative precision.
Rather than selecting analogs based on implant diameter, laboratories now choose between manual and digital workflows.
DANSE – Universal Manual Analog
The DANSE is the universal laboratory analog for conventional (manual) impression techniques.
Key features:
- Compatible with all SuperLine II implant diameters
- Universal connection design
- 12.0 mm analog length
- Designed for traditional impression workflows
Although primarily developed for SuperLine II, Dentium also lists the DANSE as compatible across the SuperLine and Implantium series. However, when restoring legacy implant systems, clinicians should always verify compatibility using the appropriate Dentium restorative catalogue.
DAN 38D – Universal Digital Analog
The DAN 38D is the digital counterpart to the DANSE and is specifically designed for digital impression workflows.
Unlike the DANSE, the DAN 38D is classified under Digital Impression Components, making it the preferred analog when working with digital models and CAD/CAM restorative processes.
Key features:
- Universal compatibility across all SuperLine II implant diameters
- Designed specifically for digital workflows
- 12.0 mm analog length
- Supports accurate CAD/CAM prosthetic fabrication
Like the DANSE, the DAN 38D is referenced as compatible across the SuperLine and Implantium series, although compatibility should always be confirmed for legacy restorations.
Quick Comparison
| Product Code | System Generation | Connection Type | Workflow | Primary Compatibility |
|---|---|---|---|---|
| DAN 34 | Legacy SuperLine / Implantium | Diameter-specific | Manual | Ø3.6 mm platform (Ø3.4 mm body) |
| DAN 38 | Legacy SuperLine / Implantium | Diameter-specific | Manual | Ø4.0–Ø7.0 mm platforms |
| DANSE | SuperLine II | Universal | Manual | All SuperLine II implant diameters |
| DAN 38D | SuperLine II | Universal | Digital | All SuperLine II implant diameters |
Choosing the Right Dentium Laboratory Analog
Selecting the correct analog depends on three factors:
- The implant system (Legacy SuperLine/Implantium or SuperLine II)
- The implant platform diameter
- Your laboratory workflow (manual or digital)
For legacy SuperLine and Implantium implants, select:
- DAN 34 for Ø3.6 mm platform implants
- DAN 38 for Ø4.0–Ø7.0 mm platform implants
For SuperLine II, the implant diameter no longer determines the analog selection. Instead, choose based on your workflow:
- DANSE for conventional impression techniques
- DAN 38D for digital impression and CAD/CAM workflows
Conclusion
Dentium’s laboratory analogs have evolved alongside its implant systems to support increasingly efficient restorative workflows.
The original SuperLine and Implantium systems rely on diameter-specific analogs, requiring clinicians and technicians to select either DAN 34 or DAN 38 according to the implant platform.
With SuperLine II, Dentium simplifies component selection through universal analogs, where the decision is based on the laboratory workflow rather than implant diameter. The DANSE is intended for conventional impression techniques, while the DAN 38D is purpose-built for digital workflows, ensuring maximum accuracy throughout the CAD/CAM restorative process.
Before selecting any laboratory analog, always verify both the implant system and the intended restorative workflow. Using the correct component from the outset helps ensure precise prosthetic fit, improved laboratory efficiency, and predictable long-term clinical outcomes.